PERRY JOHNSON LABORATORY
|
Certificate of Accreditation |
||
Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:
(Hereinafter called the Organization) and hereby declares that Organization is accredited in accordance with the recognized International Standard:
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (as outlined by the joint ISO-ILAC-IAF Communique´ dated January 2009):
Accreditation claims for such testing and/or calibration services shall only be made from addresses referenced within this certificate. This accreditation is granted subject to the system rules governing the Accreditation referred to above, and the Organization hereby covenants with the Accreditation body’s duty to observe and comply with the said rules.
For PJLA:
|
|
Initial Accreditation Date: November 20, 2003 |
Issue Date: August 23, 20ll |
Accreditation No. 59250 |
Certificate No. L11-134 |
| Perry Johnson Laboratory Accreditation, Inc. (PJLA) 755 W. Big Beaver, Suite 1325 Troy, Michigan 48084 |
The validity of the certificate is maintained through ongoing assessments based on a continuous accreditation cycle. The validity of this certificate should be confirmed through the PJLA website www.pjlabs.com |
![]() |
![]() |
Certificate of Accreditation: Supplement |
755 Larry Court, Waukesha, WI 53186
Tom Warzyn Phone:262-798-4243
Accreditation is granted to the facility to perform the following calibration:
| MEASURED INSTRUMENT, QUANTITY OR GAUGE | RANGE (AND SPECIFICATION WHERE APPROPRIATE) | CALIBRATION AND MEASUREMENT CAPABILITTY EXPRESSED AS AN UNCERTAINTY (±) | CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED |
| Optical Comarator-Linear | 0.010 in to 12 in 12 in to 24 in |
370 µin 440µin |
Glass Scale |
| Optical Comparator- Angular | 1° to 360° | 0.10° | Reference Square |
| Squareness of Y Axis to X Axis |
10 in of Y Axis travel or maximum Y travel if maximum is less than 10 in | 171 µin | Master Square |
| Optical Comparator- Magnification | 10 X 20 X 31.25 X 50 X 62.5 X 100 X |
0.061% 0.043% 0.039% 0.034% 0.022% 0.017% |
Glass Scale |
| Vision System – Stage | 6 in x 8 in 6 in x 10 in 6 in x 12 in 8 in x 8 in 12 in x 12 in 18 in x 18 in 188 in x 20 in 18 in x 24 in |
95 µin 110 µin 120 µin 100 µin 116 µin 180 µin 190 µin 214 µin |
Glass Grid |
| Vision System – Z axis | 1 in to 4 in | 71 µin | Z Step Gage |
The CMC (Calibration and Measurement Capability) stated for calibrations included on this scope of accreditation represent the smallest measurement uncertainties attainable by the laboratory when performing a more or less routing calibration of a nearly ideal device under nearly ideal conditions. It is expressed at a confidence level of 95% using a coverage factor k (usually equal to 2). The actual measurement uncertainty associated with a specific calibration performed by the laboratory will typically be larger than the CMC for same calibration since capability and performance of the device being calibrated and the conditions related to the calibration may reasonably be expected to deviate from ideal to some degree.
Issue: 8/11 This supplement is in conjuction with certificate #L11-134